“Background Unreliability of breath sounds auscultation after intubation is reportedly mainly related to the presence of the Murphy eye. This study was performed to ascertain whether an uncuffed pediatric tracheal tube with bilateral Murphy eyes increases the risk of unrecognized bronchial intubation, compared to an uncuffed tube without eyes.

Methods Following induction of anesthesia in 50 toddlers, either an uncuffed tube without eyes or an uncuffed tube with bilateral eyes was inserted into the trachea. The tube was then slowly advanced while breath sounds were auscultated using a stethoscope. In study 1, when breath sounds Selleckchem AZD8055 changed and disappeared, GDC-0994 the distance from the carina to the tube tip was measured using a fiberoptic

bronchoscope. In study 2, when breath sounds changed, the tracheal tube was withdrawn 5, 10, 15 and 20 mm while using a fiberoptic bronchoscope to ascertain whether bronchial intubation had occurred.

Results When breath sounds changed and disappeared, the tip of the tube with bilateral eyes was positioned more deeply below the carina than that of the tube without eyes. When the tube was withdrawn 10 mm from the point at which breath sounds changed, frequencies of bronchial intubation were 13% and 80% in the no eyes and double eyes groups, respectively.

Conclusion An uncuffed pediatric tracheal tube with bilateral Murphy eyes reduces the ability of breath sounds auscultation to detect bronchial intubation and may increase the risk of unrecognized bronchial intubation compared to an uncuffed tube without eyes.”
“Commonly, electroluminescence (EL) from Ge nanocrystals (Ge NCs) has been obtained by room temperature (RT) Ge implantation into a SiO2 matrix followed by a high temperature anneal. In the present work, we have JPH203 Transmembrane Transporters inhibitor used a novel experimental

approach: we have performed the Ge implantation at high temperature (T-i) and subsequently a high temperature anneal at 900 degrees C in order to grow the Ge NCs. By performing the implantation at T-i=350 degrees C, the electrical stability of the MOSLEDs were enhanced, as compared to the ones obtained from RT implantation. Moreover, by changing the implantation fluence from Phi=0.5 x 10(16) and 1.0 x 10(16) Ge/cm(2) we have observed a blueshift in the EL emission peak. The results show that the electrical stability of the hot implanted devices is higher than the ones obtained by RT implantation. (C) 2009 American Institute of Physics. [doi: 10.1063/1.3262627]“
“Objectives To assess the clinical performance of the Ambu Aura-i (Aura-i) in children. Aim To compare the Aura-i with the air-Q intubating laryngeal airway (air-Q) for the purposes of fiberoptic-guided tracheal intubation. Background The Aura-i is a new supraglottic airway designed for tracheal intubation.