It has been observed that (1) yeast. cell viability decreases as the laser fluence increases from 85 to around 1500 mJ/cm(2) and (2) some of the MAPLE DW process-induced cell damage is reversible. The post-transfer yeast cell recovery is a function of laser fluence; however, this dependence relationship is not monotonic. Future work is needed to better understand the physical and chemical mechanisms of the above GSK3235025 observations. (C) 2009 American Institute of Physics. [DOI: 10.1063/1.3202388]“
“Background: We have observed contour changes of the barium-filled

esophagus during atrial fibrillation (AF) ablation with cryo-energy delivered in direct proximity to the esophagus.

Objective: To evaluate the frequency, location, and severity of esophageal contour changes during cryo-energy application close to the esophagus.

Methods:

We retrospectively analyzed cine-fluoroscopic images acquired during hybrid cryo-radiofrequency AF ablation in 100 consecutive patients with cryo-energy delivered only in direct proximity to the esophagus.

Results: Esophageal contour changes were observed in 28 (32%) of 89 patients (and 74 [6.2%] of 1,191 of all cryo applications). They were more frequent in the left common pulmonary vein (PV) (50%) and less so in https://www.selleckchem.com/products/AC-220.html the right common PV and the upper PVs (4-5%). The distance of the ablation catheter from the endoesophageal contour prior to cryo-energy applications associated with contour changes was 1.8 +/- 1.5 mm, which increased to 4.1 +/- 1.6 mm at the time of peak contour change (P < 0.001). The esophageal contour deformation was 2.3 +/- 0.9 mm. There were no apparent complications related to cryo-energy application for 3-4 minutes, even if associated with contour changes.

Conclusion: Esophageal contour changes were observed in > 6% of cryo applications in direct proximity to

the esophagus (32% of patients) and were most frequent in the posterior aspect of the left common and right FK866 lower PV ostium when cryo-energy was delivered at a distance of <= 5 mm from the esophageal contrast silhouette. No overt esophageal injury occurred. However, the safety of cryo-energy application in direct proximity to the esophagus remains to be further confirmed.

(PACE 2009; 32:711-716).”